Main features
Produktbeschreibung | APC Smart-UPS SMT3000RMI2UC - USV - 2700 Watt - 3000 VA - mit APC SmartConnect |
Type | (Offline) UPS |
Gerätetyp | USV - Rack - einbaufähig |
Rack-Größe | 2U |
Weight | 44.28 kg |
Input voltage | Wechselstrom 220/230/240 V |
Ausgangsspannung | Wechselstrom 220/230/240 V ± 5% |
Leistungskapazität | 2700 Watt / 3000 VA |
Eingangsanschlüsse | 1 x Strom IEC 60320 C20, Netzstecker BS 1363, Strom CEE 7/7 |
Ausgabeanschlussstellen | 8 x Strom IEC 60320 C13 ¦ 3 x IEC-Jumper ¦ 1 x Strom IEC 60320 C19 |
Batterie | Bleisäure |
Anz. Batterien | 1 |
Betriebszeit (bis zu) | 3.2 Min. bei voller Last |
Netzwerk | RS-232, USB |
Colour | Schwarz |
Abmessungen (Breite x Tiefe x Höhe) | 48 cm x 68.3 cm x 8.6 cm |
Kombiniert mit | APC SmartConnect |
Entwickelt für | P/N: AR3003, AR3003SP, AR3006, AR3006SP, AR3103, AR3103SP, AR3106, AR3106SP, AR3140G, AR3340G, AR3357X674, AR4018SP, AR4018SPX429, AR4018SPX431, AR4018SPX432, AR4024IX431, AR4024SP, AR4024SPX429, AR4024SPX431, AR4024SPX432, AR4038IX432, AR9300SP, AR |
General
Gerätetyp | USV - Rack - einbaufähig |
Höhe (Rack-Einheiten) | 2U |
Colour | Black |
Kombiniert mit | APC SmartConnect |
Stromversorgungsgerät
UPS-Technologie | Line-Interactive |
Input voltage | Wechselstrom 220/230/240 V |
Eingangsspannungsbereich | Wechselstrom 160-286 V |
Eingangsspannungsbereich (einstellbar) | Wechselstrom 151-302 V |
Vorhandene Spannung | 50/60 Hz ± 3Hz |
Nötige Frequenz | 50/60 Hz ± 3Hz |
Eingangsanschlüsse | 1 x Strom IEC 60320 C20, Netzstecker BS 1363, Strom CEE 7/7 |
Angaben zu Ausgangsleistungsanschlüssen | 8 x Strom IEC 60320 C13 ¦ 3 x IEC-Jumper ¦ 1 x Strom IEC 60320 C19 |
Ausgangsspannung | Wechselstrom 220/230/240 V ± 5% - 50/60 Hz |
Leistungskapazität | 2700 Watt / 3000 VA |
Ausgabe Wellenform | Sinuswelle |
Überspannungsschutz | Ja |
Energie-Nennleistung | 365 Joules |
Schutzschaltung | Trennschalter |
Batterie
Menge | 1 |
Technologie | Bleisäure |
Laufzeit (bis zu) | 3.2 min bei Volllast ¦ 11.5 min bei halbe Beladung |
Ladezeit | 3 Stunden |
Übertragungszeit | 6 ms |
Besonderheiten | Wartungsfrei, versiegelt, leckagefrei |
Network
Remote-Verwaltungsschnittstelle | RS-232, USB |
Erweiterung/Konnektivität
Interfaces | 1 x Verwaltung (RS-232) - RJ-45 ¦ 1 x Verwaltung (USB) |
Erweiterungssteckplätze | 1 (gesamt)/ 1 (frei) x SmartSlot |
Verschiedenes
Enthaltene Kabel | Kabel seriell - extern ¦ USB-Kabel - extern |
Rackmontagesatz | Mitgeliefert |
Besonderheiten | Hörbarer Alarm, Not-Aus, LCD Anzeige, Automatische Spannungsregelung (Automatic Voltage Regulation, AVR), Kaltstartfunktion, automatischer Selbsttest, prädiktive Ausfallbenachrichtigung, im Betrieb austauschbare Akkus, Energiemesser |
Mark | CE; EN 60950; IEC; VDE |
Software / Systemanforderungen
Software inbegriffen | APC PowerChute Business Edition |
Herstellergarantie
Service und Support | Begrenzte Garantie - Austausch oder Reparatur - 3 Jahre ¦ Begrenzte Garantie - Batterien - 2 Jahre |
Umgebungsbedingungen
Min Betriebstemperatur | 0 °C |
Max. Betriebstemperatur | 40 °C |
Zulässige Luftfeuchtigkeit im Betrieb | 0 - 95% |
Geräuschentwicklung | 55 dBA |
Abmessungen und Gewicht
Width | 480 mm |
Tiefe | 68.3 cm |
Höhe | 8.6 cm |
Weight | 44.3 kg |
Abmessungen & Gewicht (Transport)
Transportbreite | 60 cm |
Transporttiefe | 98 cm |
Transporthöhe | 25.4 cm |
Transportgewicht | 51.7 kg |
Informationen zur Kompatibilität
Entwickelt für | P/N: ACCS1000, ACCS1001, ACCS1002, ACCS1003, ACCS1004, ACCS1005, ACCS1006, ACCS1007, ACDC1015, ACDC1016, ACDC1017, ACDC1019, ACDC1020, ACDC1021, ACDC2513, ACF002, ACF101BLK, ACF102BLK, ACF400, AP5017, AP5602, AP5606, AP5607, AP5616, AP92200, AP9290, AR202 |
Classification
eClass-10.1-ID | 27040601 |
eClass-11.1-ID | 27040601 |
eClass-6.2-ID | 27040601 |
eClass-7.1-ID | 27040601 |
eClass-8.1-ID | 27040601 |
eClass-9.1-ID | 27040601 |
eClass-ID | 19030401 |
UNSPSC 20.0601 Code | 39121011 |
custom tariff number | 85044030 |
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Cold-start capable
Provides temporary battery power when the utility power is out.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Energy meter
Provides actual kilowatt hours of usage for energy conscious users.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
High online efficiency
Reduces utility costs, generates less heat.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Network manageable
Provides remote power management of the UPS over the network.
Outlet group control
Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Sequenced network shutdown and reboot
Customize network shutdown and reboot sequence of connected servers and UPSs.
Serial connectivity
Provides management of the UPS via a serial port.
Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
SmartConnect
Innovative, easy to use remote monitoring feature that provides automatic notifications, firmware updates, and advanced support services.
StruxureWare Data Center Expert compatible
Enables centralized management via StruxureWare Data Center Expert.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Cold-start capable
Provides temporary battery power when the utility power is out.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Energy meter
Provides actual kilowatt hours of usage for energy conscious users.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
High online efficiency
Reduces utility costs, generates less heat.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Network manageable
Provides remote power management of the UPS over the network.
Outlet group control
Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Sequenced network shutdown and reboot
Customize network shutdown and reboot sequence of connected servers and UPSs.
Serial connectivity
Provides management of the UPS via a serial port.
Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
SmartConnect
Innovative, easy to use remote monitoring feature that provides automatic notifications, firmware updates, and advanced support services.
StruxureWare Data Center Expert compatible
Enables centralized management via StruxureWare Data Center Expert.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Review product
No review available for this product.